Doors.NET Reference Manual
- 390 -
Floor Device
Wiring Loca-
tion
Terminal
Block
Default Output
Designator
Default Input
Designator
1
6 4x4
Bus 1 - Port
2
TB23 Output 5.2 Input 5.2
7 4x4
Bus 1 - Port
3
TB24 Output 5.3 Input 5.3
8 4x4
Bus 1 - Port
4
TB25 Output 5.4 Input 5.4
9 4x4
Bus 2 - Port
1
TB22 Output 6.1 Input 6.1
10 4x4
Bus 2 - Port
2
TB23 Output 6.2 Input 6.2
11 4x4
Bus 2 - Port
3
TB24 Output 6.3 Input 6.3
12 4x4
Bus 2 - Port
4
TB25 Output 6.4 Input 6.4
13 4x4
Bus 3 - Port
1
TB22 Output 7.1 Input 7.1
14 4x4
Bus 3 - Port
2
TB23 Output 7.2 Input 7.2
15 4x4
Bus 3 - Port
3
TB24 Output 7.3 Input 7.3
16 4x4
Bus 3 - Port
4
TB25 Output 7.4 Input 7.4
17 4x4
Bus 4 - Port
1
TB22 Output 8.1 Input 8.1
18 4x4
Bus 4 - Port
2
TB23 Output 8.2 Input 8.2
19 4x4
Bus 4 - Port
3
TB24 Output 8.3 Input 8.3
20 4x4
Bus 4 - Port
4
TB25 Output 8.4 Input 8.4
l The Output is the Door Relay for each floor.
l The Input is the Cab Request for each floor. Cab Request Inputs are only
used/wired if the cab reader is set to Elevator - With Floor Select. Use this option
when you need to know the floor that was selected; which is a different behavior
than the default option of Elevator - No Floor Select.