Doors.NET Reference Manual
- 165 -
Global Unlock/Lock and Situation Manager
The Global Unlock/Lock features used by PXL controllers in Doors32 are also available
in Doors.NET. These features use dedicated inputs on the master PXL controller to
either unlock or lock all online, functioning doors in the network.
Doors.NET also has a Situation Manager feature providing additional capabilities for
controllers in global unlock/lock applications. This feature provides greater control and
flexibility in how Global Unlock/Lock is implemented, including varying restriction levels
of lock and unlock, and the ability to assign/unassign specific doors to the global unlock-
/lock commands.
Situation Manager features are fully supported by the following controllers:
l NXT
l Mercury Powered NXT
l Standard Mercury
l Ingersoll/Rand Schlage
l PXL with firmware v8.06.09 or greater (all PXL controllers on the network must
have this firmware revision or greater)
Situation Manager features are partially supported by the following controllers:
l ASSA Aperio only supports Lock and Remote Lock Out
(can take up to 1 minute to process cannot do lock down)
l ASSA WiFi/POE only supports Remote Unlock/Lock
(applies only to lock sets configured as Always On)